What the service includes

What we check in an emergency PA system

01

Consoles and microphones

Checking the PA consoles, zone selection and the pre-recorded messages.

02

Amplifiers and power sources

Checking the amplifiers, power supplies and backup power for operation during a power cut.

03

Loudspeakers and lines

Checking the loudspeaker lines and that the loudspeakers in every zone are working.

04

Audibility and coverage

Making sure the message is audible and clear in all the defined zones, including noisy areas.

05

Activation from fire detection

Checking the interface that triggers an automatic evacuation message during an event.

06

Documentation and certificate

Recording the inspection and preparing the emergency PA compliance and maintenance certificate form (Form 6) when it is required.

How we work

We test the PA as if it were a real event.

Not just that the system is on — but that the message reaches everywhere it needs to.

  1. Equipment check

    Consoles, amplifiers, power sources and backup.

  2. Zone check

    Playback in every zone and an audibility check.

  3. Scenario test

    Activation from the fire detection system and checking the message.

  4. Documentation

    Inspection report and forms as needed.

Operational PA and emergency PA

Everyday PA and emergency PA — not always the same system.

Many buildings also have a PA system for day-to-day use. We check whether the existing configuration meets the requirements for emergency PA — and in many cases the systems need to be separated. You can read about setting up new systems on the PA systems page.

An emergency PA system: what we check and why

An emergency PA system is meant to play a clear evacuation message in every zone of the building during an event. It is usually connected to the fire detection system, must keep working during a power cut, and is tested under SI 1220 Part 3 — which is why testing it differs from testing an ordinary PA system.

What the inspection includes

  • The PA consoles, microphones and pre-recorded messages
  • Amplifiers, power supplies and backup power
  • Monitoring of the loudspeaker lines and the loudspeakers in every zone
  • Audibility and clarity of the message, including in noisy areas
  • Automatic activation from the fire detection system

Emergency PA compliance certificate

The Fire and Rescue Authority sometimes requires a compliance and maintenance certificate for the voice evacuation system (Form 6) as part of business licensing. The form is available in the fire department forms library. We inspect and maintain such systems in businesses and institutions in the North — from Netanya and Hadera, through Haifa, Afula and Nof HaGalil, to Kiryat Shmona and the Golan Heights.

Illustration: Emergency PA

Frequently asked questions

Frequently asked questions about emergency PA

How is emergency PA different from an ordinary PA system?

Emergency PA is connected to the safety systems, takes priority over any other use and must keep working during a power cut.

The building uses the same system for routine announcements too — is that a problem?

It depends on the configuration. We check whether the system meets the emergency requirements — priority for the evacuation message, backup power and line monitoring — and in many cases we recommend separating the systems.

Do you check systems from different manufacturers?

Yes. The inspection is based on how the system is required to operate, not on a particular manufacturer.

Can the inspection be combined with fire detection system maintenance?

Yes, and it is recommended — that way the interface between the two systems is also checked in the same visit.

How often does the system need to be inspected?

The frequency is set by the standard and the building’s licensing requirements. It is recommended to combine the inspection with fire detection system maintenance, to check the interface between them too.

Which areas do you provide the service in?

Across the North — from Netanya and Hadera, through Haifa, Afula and Nof HaGalil, to Kiryat Shmona and the Golan Heights.

Need an inspection for your emergency PA?

Tell us about the type of building and the number of zones, and we'll schedule an inspection.

Contact us on WhatsApp →