System Integration / Automatic evacuation message

Connecting PA to Fire Detection — Automatic Evacuation Message

Connecting the PA system to the fire detection system: in an event an automatic evacuation message is played in the right zones — immediately, without waiting for someone to reach the console.

Example scenario

How the evacuation message goes out by itself

  1. A smoke detector detects an event on a certain floor and reports to the panel.
  2. The panel activates the PA system according to the zone where the event started.
  3. Each zone hears the recorded message set for it, without waiting for a person to make the announcement.

The scenario is illustrative. The actual activations are set according to the building's design and the safety consultant's instructions.

What the service includes

What the connection includes

01

Defining scenarios

What is heard, where and when — for every type of event and every zone.

02

Recorded messages

Preparing clear evacuation messages, in the language and wording that suit the building and its users.

03

Activation by zone

Playback in the event zone, in adjacent zones or throughout the building, according to the design.

04

Emergency priority

The emergency message overrides any other use of the system and is heard in all the defined zones.

05

Manual control

A paging station that allows staff to give additional instructions in real time.

06

Testing and maintenance

Testing the interface as part of the periodic maintenance of both systems.

How we work

The right message, in the right zone.

Every scenario is defined in advance and tested for real before the system is handed over.

  1. Zone planning

    Dividing the building into PA and evacuation zones.

  2. Preparing messages

    Wording and recording the evacuation messages.

  3. Connection and configuration

    Interface between the systems and configuring the scenarios.

  4. Scenario test

    Activation from fire detection and testing in every zone.

Integrating with what already exists

You don't need to replace the PA system to connect it.

In many cases an existing emergency PA system can be connected to the fire detection system using a suitable interface. If the system is also used for routine announcements, we check that it meets the requirements for emergency PA. See also: PA systems and emergency PA.

Automatic evacuation message: why a sounder alone isn't enough

A sounder tells people there is an event. An evacuation message tells them what to do. Connecting PA to fire detection makes it possible to play a pre-recorded message — clear, in the right language and with tested wording — the moment the fire detection system detects an event.

Evacuation by zone and floor

In large buildings it isn’t always right to evacuate everyone at once. When the PA system is divided into zones, an evacuation message can be played on the floor of the event and the adjacent floors, and a standby message in the rest of the building — according to the scenario set in the design.

Part of the emergency PA and the activation regime

Automatic activation is part of the emergency PA system, and in buildings that require an activation regime test it is tested as part of the scenario. We design the scenarios, prepare the messages, connect the systems and test every zone for real. The service is available in the North — from Netanya and Hadera, through Haifa, Afula and Nof HaGalil, to Kiryat Shmona and the Golan Heights.

Illustration: PA + Safety Systems

Frequently asked questions

Frequently asked questions about connecting PA to safety systems

Can a message be prepared in several languages?

Yes. Messages can be recorded in several languages and played in sequence, according to the building’s population.

What is the difference between a sounder and a recorded message?

A sounder warns that there is an event; a recorded message also tells people what to do and where to exit.

Can a message be played only on the floor of the event?

Yes, if the PA system is divided into zones. At the design stage the zones and the playback order are defined.

Does this replace the emergency PA?

The connection is part of the emergency PA system — it adds automatic activation from the safety system.

Can the wording of the message be changed later?

Yes. Messages can be re-recorded and updated, and after every change it’s recommended to test the scenario again.